seo_product_factory_title

Si necesita ayuda con el producto, visite la página de soporte
materiales de apoyo
Unit Net/Gross weight
19.84/25.35
Unit dimensions (W*H*D)
35.63x7.80x10.83
SEER
15
Room temperature Heating
32~86
Room temperature Cooling
62~90
Rated Current Heating
8.0
Rated Current Cooling
8.7
Power source
208-230V,1Ph,60Hz
  • Easier Installation and maintenance.
  • Release negative ions, and eliminate odor, dust, smoke, and pollen particles to give you fresh and healthy air.
  • Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.
  • When the system has leakage or compressor overload, the display board will show
    “EC” to alarm users which can better prevent the compressor from being damaged.
  • When you start the unit next time, the angle of the horizontal louver will automatically
    move to the same position as you set last time.
  • When turns off the unit on COOL, DRY, or AUTO (Cool) modes, the air conditioner will continue operating for about 10 minutes (depending on the model) at LOW fan speed. This will help to dry up the condensed water inside the evaporator and prevent the breeding of mildew.
    Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.
  • For heat pump models, after running in cooling or drying mode, if the user press the “Self Clean” button on the remote controller, firstly, the indoor unit runs in the fan-only mode for a while, then low heat operation, and finally runs in fan-only again. This function can keep the inside of the indoor unit dry and prevent the breeding of mold.
    The advantage for end-user: This function can keep the inside of the indoor unit dry and prevent the breeding of mildew, supplying clean and healthy air to people.
  • The advantage for the end-user: With this function, the room temperature sensor built-in remote controller is activated and replaces the one in the indoor unit. Then the air conditioner will regulate the room temperature based on the temperature around the remote controller, just like the air conditioner is following the user.
    Pressing the “Follow me” button on the remote controller to activate this function. Then the remote controller will send PCB the signal every three minutes. If the PCB doesn’t receive the signal for 7 minutes or presses the “Follow me” button again, the follow me function will terminate.